Validation strategy and evidence

Current evidence boundary

As of the Phase 0–10 review on 2026-09-06, the suite contains 170 passing internal tests. These establish many analytical identities, input contracts, conservation properties, and deterministic wrapper relationships. They do not establish engineering validity for the combined solver. Several higher-level tests compare one package entry point with another path through the same implementation, so they are regression tests rather than independent hydraulic oracles.

Missing evidence includes additional independent published water-surface-profile and hydraulic-jump benchmarks, mixed free-surface/pressurised transitions, and external comparisons beyond the bounded normal-depth and HY-8 matrices below. Performance thresholds are development regressions and do not imply hydraulic correctness.

Manning channel tailwater fixtures

CS-029's first bounded increment adds hand-calculated SI fixtures for rectangular, symmetric trapezoidal, asymmetric trapezoidal, and triangular sections. The asymmetric fixture uses b=4 m, side slopes 3H:1V and 2H:1V, y=1.2 m, n=0.035, and Sf=0.002: A=8.4 m2, P=10.4780147652 m, section factor A R^(2/3)=7.2490229165 m^(8/3), and Q=9.2624617210 m3/s. The solved depth tolerance is 1e-7 m; geometry checks use 1e-9 relative or absolute tolerance where applicable.

Tests separately force automatic bracket expansion, zero-flow and invalid-slope contracts, total-crossing-flow resolution before an unequal group split, full provenance retention, and per-point tailwater recalculation in a rating curve. Existing fixed-stage, roadway, barrel, crossing, and rating tests remain regression gates. These equation-level fixtures validate the transcription and integration. The external comparison below validates the bounded prismatic normal-depth calculation, but not a downstream backwater model or the suitability of project roughness, slope, or geometry.

HEC-RAS 7.0.1 normal-depth comparison

The retained eight-row comparison is validation_data/hecras_7_0_1_normal_depth.csv, SHA-256 bd5dd2b6da1e965b9ab46ed18d2c03436154ee165c5bed48f81ba759d6bfed97. It was generated on Windows through COM controller RAS701.HECRASController, which reported HEC-RAS 7.0.1 June 2026. The installed Ras.exe file version was 7.00.0001 and its SHA-256 was ce2ca395c68c4ee17387376ea3a7152c24db483488dced4eb96a59e85fd72985.

The seed was the official HEC-RAS 7.0 example directory 1D Steady Flow Hydraulics/Mixed Flow Regime Channel. The source MIXED.PRJ, MIXED.g01, MIXED.f01, and MIXED.P01 SHA-256 values were respectively b0a6d0cad552cc02d9910e147f9704bf58546ba88f6897b7ea6bb7fcc893fb61, 28d264546fabfae32590f369e8d2a7e90099af26fc9678512b4b599f843b5529, a0c50328fdf645d93b0d7bc1be7ac926fa1252505f7dce531ad37b925ad62e32, and d9d7603042601db759779902b688dfb86581508cd5b58ac28770d176a3b07f0c. The source advertises Program Version=6.30 internally but was supplied in the 7.0 example pack and was executed only with the version-pinned 7.0.1 controller.

scripts/compare_hecras_normal_depth.py copies the source project into an ignored workspace and never edits the download. For each case it removes stale HDF/results while copying, replaces all cross sections with one prismatic section inside a 10 m-deep envelope, preserves the original reach layout and section inverts, applies one Manning roughness over the complete wetted section, and sets both boundaries to normal depth with the stated friction slope. The source project remains in English units; the adapter converts explicit SI inputs to feet and cubic feet per second, formats flow to seven significant digits, and uses the discharge returned by HEC-RAS for the matched local calculation.

The matrix covers rectangular, symmetric trapezoidal, asymmetric trapezoidal, and triangular sections, each at 0.5 m3/s and a higher flow between 2.342083 and 9.262461 m3/s. Bottom width, independent side slopes, Manning roughness, friction slope, effective SI and HEC-RAS discharges, both depths, and their signed difference are retained in every row. HEC-RAS flow area, wetted perimeter, and top width are also retained to prove geometry parity. Their maximum absolute differences from the intended SI section were respectively 0.00001513 m2, 0.00001348 m, and 0.00001283 m, within the explicit 0.00002 geometry tolerance.

The maximum absolute normal-depth difference was 0.00014520 m, within the comparison tolerance of 0.0002 m at every point. This tolerance captures the observed version-pinned software and legacy text-input precision; it is not a field or design tolerance. The comparison was fully automated and was not manually reviewed in the HEC-RAS GUI. It is external uniform-flow evidence only and does not supersede the primary Manning equation or validate downstream impoundment, constriction, junction, tidal, or other backwater effects.

Reproduce it from the repository root with HEC-RAS 7.0.1 and pywin32 installed:

python -B scripts/compare_hecras_normal_depth.py `
  --template "reference_docs/Example_Projects_7_0/1D Steady Flow Hydraulics/Mixed Flow Regime Channel" `
  --workspace "validation_artifacts/hecras-normal-depth" `
  --output "docs/validation_data/hecras_7_0_1_normal_depth.csv"

The workspace must not already exist; this prevents an earlier HEC-RAS run from being silently reused or overwritten.

The provenance tests distinguish the HDS-5 method reference from independent project sources for roughness, slope, geometry, and invert. The ambiguous source field is intentionally rejected in favour of explicit provenance names. Channel normal depth and culvert-outlet-relative tailwater depth remain separate, explicitly documented result quantities.

The user-supplied rating-curve boundary has contract tests for exact points, linear interpolation including a flat-stage segment, nonfinite point values, insufficient points, negative, duplicate, and decreasing discharge, decreasing elevation, and requests below or above the supplied range. Forward integration tests exercise barrel flow, total group flow, and total crossing flow before unequal-group allocation. A crossing rating test independently resolves the boundary at every requested total discharge and checks the retained curve, project source, interpolation decision, requested flow, and elevation. These tests establish interpolation and integration behavior; the user-supplied curve itself remains project evidence whose validity is the caller's responsibility.

Coupled inverse-tailwater regression tests perform forward/inverse round trips for a single barrel, the barrel HW/D convenience, an identical three-barrel group, and a mixed circular/rectangular crossing. They confirm that Manning stage is resolved from barrel, total group, or total crossing discharge as applicable. A separate mixed-crossing case keeps both culvert and unsubmerged roadway flow active. User-rating-curve tests recover an in-range flow and reject target headwaters that would require either extrapolation direction. These are consistency and boundary-contract tests, not independent hydraulic validation of the combined inverse method.

Corrected modern-box fixture

tests/test_modern_box.py checks the corrected FHWA-HRT-06-138 transcription and applicability boundary. It verifies net area and depth-dependent geometry for equal 45-degree corner fillets, resolves the Appendix D FC-D-30 physical inlet to Figure 93 Sketch 2 and Ke = 0.32, checks the dimensionless Table 12 polynomial, and rejects both unsupported configurations and results outside approximately 0.4 < HW/D < 2.3.

The Q25 fixture uses the report's authoritative customary-unit inputs. It reproduces the Table 22 critical depth of 3.88 ft and Table 25 pool water elevation of 85.907 ft. The pool result converts the calculated energy grade using the published 1265 ft2 approach area; a general discharge-dependent approach-section model remains future work.

Foundation milestone

The active tests are analytical and contractual, independent of legacy outputs. tests/test_foundations.py covers:

  • An irrational analytical root, decreasing functions and endpoint solutions.
  • Tiny residuals whose scale must not cause premature convergence.
  • Very large positive and opposite-sign brackets without overflow.
  • Separate residual and coordinate tolerances.
  • Explicit iteration exhaustion and floating-point resolution failures.
  • Invalid bounds/counts/tolerances and nonfinite function evaluations.
  • Millimetre conversion, invalid dimensions and floating-point underflow.
  • Specific source locators and frozen result/configuration records.

Test counts and executed checks are recorded in progress. Package build/import checks also verify the new source layout and typed marker.

Numerical tolerances versus engineering acceptance

Root defaults (x_abs=1e-10, x_rel=1e-12) are algorithm settings. Hydraulic callers must choose tolerances in appropriate units and scales. There is no global percentage acceptance limit and these defaults are not design accuracy.

Quantity Planned internal oracle Acceptance basis
Area/perimeter/top width Analytical empty/partial/full geometry Absolute + relative numerical error
Critical depth Rectangular closed form and independent circle cases Depth error and Fr residual
Normal depth Independently computed Manning cases Depth and discharge residual on selected branch
Full-flow losses Energy balance and direct SI equations Head loss residual and physical sensitivity
Profiles Uniform flow and published reference profiles Elevation, energy and step refinement
Group/crossing flow Conservation and independent barrel sums Absolute flow closure and partitioning

Set numerical values per fixture when independently deriving its expected result. Record source precision separately from solver tolerance. Tests must cover failure and applicability boundaries, not just successful cases or inverse self-consistency.

Representative-barrel applicability contract

Multi-barrel CulvertGroup results carry the stable representative_barrel_equal_flow applicability code and NCHRP 734 Chapter 5 provenance. The notice states that representative-barrel superposition supports total-flow calculation under sufficiently uniform approach conditions while individual-barrel discharge and velocity remain uncertain under nonuniform approach flow or depressed-barrel conditions. The published differences recorded in the research notes are limitations, not correction factors; the hydraulic calculation still uses Q_barrel = Q_total / N without an arbitrary efficiency reduction.

Focused tests verify the structured notice and source on multi-barrel group and crossing results, its absence for a single-barrel group, unchanged discharge conservation, and code and source propagation through inventory group/crossing summaries.

Hydraulic result status contract

HydraulicResultStatus distinguishes clean results, supported results with applicability advisories, results using an explicit approximation, and hydraulically unresolved results. High-head inlet-control extension warnings are advisories; the inlet-control outlet-depth fallback is approximate; mixed_flow_not_resolved is unresolved. When multiple warnings exist, the most conservative status governs. Group and crossing aggregation ignores inactive zero-flow groups, while rating points and inventory summaries retain the status of the underlying calculation. Status describes computational/hydraulic resolution only; it does not confer regulatory approval or engineering design acceptance.

Contract tests cover all four states, conservative mixed-result aggregation, inactive-group handling, rating-point retention, and inventory group/crossing propagation.

Independent primitive fixtures

The following CS-006 fixtures use fixed expected values calculated independently of the public solver entry points. HDS-5 printed page 1.15, Equation 1.1 supplies the critical-flow condition; Appendix B, Equation B.3 supplies SI Manning flow; and printed pages 3.9-3.10, Equations 3.1-3.5 supply the full-flow energy and loss relationships. Calculations use the project gravity constant g = 9.80665 m/s²; source equations are not precision-limiting, so the listed tolerances are numerical comparison tolerances rather than design accuracy.

Fixture Inputs Independent expected result Solver difference Test tolerance
Circular full geometry D=1.0 m A=0.7853981633974483 m², R=0.25 m 0.0 at shown precision relative 1e-14
Rectangular critical flow b=2.0 m, Q=6.0 m³/s yc=0.9717933987105833 m, Ec=1.457690098065875 m 0.0 at shown precision relative 1e-12
Rectangular Manning flow b=2.4 m, S=0.002, n=0.013, Q=2.6893095773667723 m³/s yn=0.6 m, K=0.7817522735793332 m^(8/3) 0.0 at shown precision depth absolute 1e-6; conveyance relative 1e-12
Circular full-flow losses D=1.0 m, L=100 m, Q=2.0 m³/s, n=0.013, Ke=0.5, Ko=1.0 He=0.16531016588512945 m, Hf=0.6958467261846067 m, Ho=0.3306203317702589 m, HL=1.191777223839995 m 0.0 at shown precision relative 1e-12

These fixtures separate geometry, critical flow, uniform flow, and loss transcription from the numerical solvers that consume them. They do not validate profile selection, mixed free-surface/pressurised transitions, groups, crossings, or rating curves.

Independent prismatic profile fixtures

CS-004 profile references were calculated outside the package entry points using the continuous gradually varied-flow relation dx/dy = (1 - Fr²) / (S0 - Sf), independent circular/rectangular section formulae, fixed-panel numerical quadrature, and bisection in depth. The JS1 reference additionally solves equality of the independently evaluated circular hydrostatic momentum functions. Production calculations use direct depth steps; the reference calculation therefore exercises a separate integration implementation.

Profile Inputs and boundary Independent expected result Refined solver difference Acceptance tolerance
S2 Circular D=1.2 m, L=30 m, S0=0.01, n=0.012, Q=1 m³/s, critical inlet outlet depth 0.4136573803 m less than 1e-8 m absolute 1e-6 m
S1 Same barrel and flow, outlet depth 1.0 m inlet depth 0.6439884203 m less than 3e-7 m absolute 1e-6 m
JS1 Same barrel and flow, outlet depth 0.75 m jump station 25.60633937 m less than 6e-5 m absolute 0.005 m
M2 Rectangular 2.0 m x 1.5 m, L=50 m, S0=0.002, n=0.013, Q=3 m³/s, critical outlet inlet depth 0.7301922412 m less than 3e-7 m absolute 1e-6 m
M1 Rectangular 2.0 m x 1.5 m, L=60 m, same slope/roughness/flow, outlet depth yn+0.3 m inlet depth 0.9790035248 m less than 5e-8 m absolute 1e-6 m
H2 Circular D=1.2 m, L=40 m, S0=0, n=0.012, Q=1.5 m³/s, critical outlet inlet depth 0.8774316585 m less than 4e-7 m absolute 1e-6 m
Mixed M2/full Circular D=1.2 m, L=100 m, S0=0.001, n=0.012, Q=3 m³/s, critical outlet crown station 68.4449163 m 0.000275 m at 800 steps absolute 0.0005 m

These are numerical method-validation tolerances, not field or design-acceptance tolerances. They do not make HY-8 the oracle and do not address non-prismatic barrels.

Independent aggregation and rating fixtures

CS-006 system fixtures were calculated outside package entry points. HDS-5 Section 3.3, printed page 3.26 (local PDF page 108), states that a manual multiple-barrel calculation typically divides discharge evenly between identical barrels and requires a software solution when barrel properties or elevations differ. The fixed full-flow headwater below uses HDS-5 Equations 3.1–3.5, printed pages 3.9–3.10 (local PDF pages 91–92).

HDS-5 Sections 3.2.1–3.2.2, printed page 3.20 (local PDF page 102), require performance curves to evaluate inlet and outlet control over a series of flows. The rating fixture uses independent circular-section formulae and bisection for critical depth, Appendix A Equations A.1/A.3, and a separate implementation of the documented project cubic-Hermite transition. It spans all three accepted inlet-control branches without using another public package API as its oracle.

Fixture Inputs Independent expected result Observed difference Acceptance tolerance Regime agreement
Three-barrel group Circular D=1 m, L=50 m, S0=0.01, n=0.013, Qtotal=6 m³/s, TW=11 m Qbarrel=2 m³/s, HW=11.843853860747691 m 0 m³/s, less than 1e-14 m exact flow split; HW absolute 1e-9 m full outlet control
Unequal-size groups of identical barrels One-barrel plus three-barrel groups, same barrel, Qtotal=8 m³/s, TW=11 m group flows 2 and 6 m³/s, common HW=11.843853860747691 m less than 2e-15 m³/s; less than 2e-15 m flow absolute 1e-5 m³/s; HW absolute 1e-6 m both groups full outlet control
Inlet-control rating curve Circular D=1 m, L=25 m, S0=0.02, n=0.012, TW=49.5 m; Q=(0.3, 1.0, 1.626, 2.5) m³/s HW=(50.41129639578769, 50.85046073327805, 51.21952069304025, 51.98257475067179) m less than 1e-14 m HW absolute 1e-9 m unsubmerged, unsubmerged, transition, submerged

CS-010 adds an equation-level roadway fixture evaluated independently from HDS-5 Equation 3.9: for C_d=1.6 m^0.5/s, L=25 m, and H_wr=0.5 m, the expected flow is 14.1421356237 m³/s. Tests also cover zero flow at the crest, explicit rejection when tailwater exceeds the crest, a roadway-only solution below a higher culvert inlet, and combined culvert/roadway conservation to 1e-5 m³/s. These are free-flow software and equation fixtures, not validation of the caller's coefficient selection or submerged flow.

These fixtures validate identical-barrel conservation and fixed-boundary rating assembly. The following external fixture adds unequal-barrel flow division; tailwater rating relationships, storage routing, irregular road crests, and submerged roadway overtopping remain outside this evidence.

Heterogeneous crossing and regime-transition rating fixture

The CS-006 issue #8 increment compares a mixed crossing against FHWA HY-8 8.0.1.2 through the installed run-hy8 2026.9.8.1 wheel. That wheel records SHA-256 efacb82b13f0fc07fa239a9db91a3e329e87f6622e53e3c5d92525848ca70a1e and source commit d3f0dbd4f85fb4aa195ade478c9a407a0bb3c0c5; the local solver commit was dd6b0ca303bb769e9d419ab60042b37a47840c5e. HY-8 is independent comparison evidence, not the equation authority.

The SI crossing has constant tailwater elevation 99.0 m and no roadway flow. Group 1 is one 1.0 m circular concrete barrel, 40 m long, with inlet/outlet inverts 100.0/99.0 m, n=0.013, and a square-edge headwall. Group 2 is two 1.2 m x 0.8 m concrete box barrels, 30 m long, with raised inlet/outlet inverts 101.0/99.5 m, n=0.015, and square edges with 30-to-75-degree wingwalls. Local inlet and entrance-loss records match those semantic HY-8 configurations. Both programs use their documented default profile option; the comparison does not tune equations or coefficients to the result.

Six total flows, Q=(0.5, 1, 2, 3, 5, 8) m3/s, span an inactive raised box group, its activation, distinct group regimes, and finally both groups in their higher-flow state. The captured result is validation_data/hy8_8_0_1_2_heterogeneous_crossing.csv, SHA-256 75bb43f9bf354fe12e8544b2ff61b80b989c6a3b641bbd90da0e0eb7ad35dd72.

Quantity Maximum absolute difference Acceptance tolerance Disposition
Common headwater 0.023668 m 0.03 m Pass at all six flows
Per-group discharge 0.017134 m3/s 0.02 m3/s Pass for both groups at all flows
Per-barrel outlet velocity 0.028003 m/s 0.03 m/s Pass for both groups at all flows
Local total-flow closure 4.10e-10 m3/s 1e-5 m3/s Pass
Local common-headwater spread 1.61e-10 m 1e-6 m Pass
HY-8 displayed-flow closure 0.00 m3/s 0.011 m3/s Pass

HY-8 reports the raised box as 0-NF at 0.5 and 1.0 m3/s. At 2, 3, and 5 m3/s, it reports the circular group as 5-S2n and the box group as 1-S2n; both are 5-S2n at 8 m3/s. The local rating result progresses from unsubmerged inlet control, through mixed while the two active groups differ, to submerged inlet control. The labels are method-specific and are not asserted as exact synonyms; the activation and differing- group-state progression agree.

The acceptance tolerances account for HY-8's two-decimal report precision plus the known difference between direct HDS-5 relationships and HY-8 fitted inlet curves. They are software-comparison tolerances, not field or design tolerances. The source-tree run and a second run with PYTHONPATH cleared against the installed ryan-culverts distribution produced byte-identical CSVs.

Later hydraulic and external gates

Validate primitives before inlet/outlet control. Cover each regime and reject inconsistent candidate solutions before integrating a barrel or crossing solver. Check continuity only where physically expected; investigate branch transitions.

Initial HY-8 executable comparison (2026-09-07)

The first executable comparison is now reproducible with scripts/compare_hy8.py. The complete captured result matrix is retained in validation_data/hy8_8_0_1_2_matrix.csv. It used:

  • FHWA HY-8 HY864.exe file/product version 8.0.1.2;
  • installed run-hy8 distribution 2026.9.8.1, source commit d3f0dbd4f85fb4aa195ade478c9a407a0bb3c0c5; the validation wheel SHA-256 is efacb82b13f0fc07fa239a9db91a3e329e87f6622e53e3c5d92525848ca70a1e;
  • initial ryan-culverts commit 1f78b3280f82169b19d059ff6509636091d87d83; the CSV was regenerated during CS-008 from commit 647ff6c06d97b65f901529b53074a76115027e4d after the documented CS-003/004 diagnostic corrections;
  • SI units, one barrel, no roadway overtopping, HY-8's default profile option, and matched shape, material, entrance, dimensions, invert levels, Manning roughness, discharge, and constant tailwater.

The comparison harness now rejects a nearest result row more than 0.0051 m³/s from the requested flow, any non-finite result, and any displayed roadway discharge above 0.0051 m³/s. It also requires exactly one indexed per-culvert diagnostic, checks its discharge, outlet velocity, and flow type against the crossing summary, and verifies that its full/free lengths sum to the configured barrel length. These tolerances only accommodate HY-8's two-decimal report precision; they are not hydraulic acceptance tolerances.

HY-8 control-depth qualifiers

The qualifier is retained separately from the numeric depth and must be included when interpreting or exporting a comparison result:

  • * on an outlet-control depth means HY-8 calculated a negative depth and replaced it with 0.0 because the implied headwater was below the inlet invert. HY-8 developer Eric Jones documents this behaviour in HY-8 Insider Article 15.
  • ** on an inlet-control depth is treated as an extreme-headwater warning. Executable tests with HY-8 8.0.1.2 observed it beginning at approximately inlet-control HW/D > 10. The installed manual does not define the marker, so neither the threshold nor meaning is a cross-version contract. Preserve it as version-specific evidence.

HDS-5 Section 3.5.2, printed page 3.39 (local PDF page 121), provides the independent engineering caution: the laboratory inlet curves cover 0.5 <= HW/D <= 3.0, with a general orifice relationship fitted at HW/D = 3.0 for larger values. Consequently, an unqualified numeric parse does not make an extreme result ordinarily validated. The adopted CS-003 policy retains the direct numeric result but attaches a stable high-head warning above HW/D = 3 and an additional extreme-headwater warning above HW/D = 10. CS-008 owns preservation of the external qualifier in comparison evidence.

Type 6 harness audit

The large Type 6 inlet-headwater difference triggered a direct audit rather than an assumption that HY-8 or run-hy8 was authoritative. The installed executable reports file and product version 8.0.1.2. The repository's reference_docs/ShapeDB.dat and HY-8 User Manual are byte-for-byte identical to the installed files under C:\Program Files\HY-8 8.00, with SHA-256 values 2479e9444feaff529313e18a1b26fc2de4f6b6c541db58477da6bebc602164a7 and 267fef1f838945dcf7c0524ddd30c0b972e24abd3ace0eaec39d9aad8402a4f5.

The HY-8-saved project contains one 0.9 m circular corrugated-steel barrel, 10 m length, inverts 100.2/100.0 m, Manning n 0.020 on top and bottom, constant tailwater 100.1 m, and contextual inlet index 2. The installed ShapeDB identifies that index as "Square Edge with Headwall." The raw .rst reports Q = 4.63 m³/s, zero roadway flow, Type 6-FFc, inlet-control depth 7.61 m, outlet-control depth 6.29 m, velocity 7.28 m/s, full length 10.00 m, and free length 0.00 m; run-hy8 returns those same values through the per-culvert result API.

The local HDS-5 outlet-control depth is 6.297 m, so the large governing difference is not evidence of a barrel-loss or result-parser error. The local inlet depth of 7.196 m is the direct Appendix A Equation A.3 result using Table A.1 Chart 2 Scale 1 constants c = 0.0379, Y = 0.69, Ks = -0.5, slope 0.02, and q* = 13.893. HY-8 instead reports the result of its documented polynomial-based inlet method. The audit did not independently reconstruct the executable's treatment at this high HW/D. It found no issue to raise against run-hy8, but it does not prove HY-8's closed executable method correct outside the scenarios and report fields exercised by the harness.

The 20-case matrix covers circular concrete, circular corrugated steel, and concrete box barrels under low and high discharges and low, intermediate, and submerged tailwaters, two cases at q* = 3.75 inside the HDS-5 transition interval, and explicit in-barrel JS1, inlet-reaching S1, long-barrel mixed M2/full-flow, and Type 6-FFc cases. HY-8 reports headwater to 0.01 m and velocity to 0.01 m/s, which limits the precision of comparisons made through its reports.

Case family Cases Maximum absolute HW difference Maximum absolute velocity difference
Circular concrete 11 0.012 m 0.015 m/s
Circular CSP, implemented paths 3 0.007 m 0.003 m/s
Circular CSP, unresolved Type 6 1 0.414 m 0.002 m/s
Concrete box 5 0.057 m 0.019 m/s

The per-culvert candidate fields make the source of those governing differences more specific. Local outlet-control depth is within 0.008 m of HY-8 in every case. The largest inlet-control depth differences are the retained Type 6 CSP case (0.414 m) and the box transition case (0.057 m), consistent with the documented differences between direct HDS-5 equations and HY-8's fitted inlet curves.

All three fully submerged Type 4-FFf cases agreed within 0.007 m headwater and 0.004 m/s velocity. The local solver now routes the steep-slope S2n profile from critical depth toward normal depth. Where tailwater exceeds normal depth, a momentum-function solve determines whether it can sustain the conjugate depth of the S2 outlet section. The moderate-tailwater circular case cannot, so its jump is swept out and S2 remains valid, matching HY-8's 1-S2n classification. This reduced the maximum circular-concrete velocity difference from 0.178 m/s to 0.015 m/s; the maximum box difference remains 0.019 m/s.

The new jump case locates the S2-to-S1 transition at station 25.584 m; its headwater and velocity differ from HY-8's 1-JS1t outputs by 0.012 m and 0.005 m/s. The higher tailwater case correctly routes S1 to the inlet and selects the free-surface outlet-control candidate, agreeing with HY-8 1-S1t within 0.005 m and 0.003 m/s. Removing the old full-flow-candidate shortcut also exposes the valid Type 7-M2c profile: its headwater difference fell from 0.089 m to 0.004 m.

For the long circular barrel, the default M2 profile reaches the crown at station 68.463 m from the inlet. Treating the upstream reach as full and continuing with full-section friction gives 12.015 m headwater versus HY-8's 12.02 m, while outlet velocity differs by 0.003 m/s. The result is explicitly classified outlet_control_mixed and retains the full-flow length rather than presenting the entire barrel as free-surface flow. HY-8's new diagnostic reports 69.48 m full and 30.52 m free, revealing a 1.017 m transition-location difference at the default discretisation despite its outlet-control depth agreeing within 0.005 m. The HY-8 plot places the crown transition at station 69.4755 m. An 800-step calculation gives 68.44519 m; an independent composite-Simpson evaluation of the continuous gradually varied-flow integral gives 68.4449163 m. Refinement therefore converges to the independent energy-balance result rather than HY-8. The previous local endpoint stopped at D - 0.0001 m; it now lands deterministically on the exact crown. The remaining approximately 1.031 m HY-8 difference is retained as a profile-method detail, not used to tune the local integration.

The shallow submerged-outlet path now routes the upstream free-surface reach to the HGL-crown transition instead of stopping after reporting the downstream full segment. For Q = 1.0 m³/s, the solver reports 0.106 m of downstream full flow and an upstream S1 curve; headwater and velocity differ from HY-8 1-S1f by 0.002 m and 0.005 m/s. For Q = 3.0 m³/s, momentum matching locates a JS1 jump at station 17.528 m before 0.202 m of downstream full flow. HY-8 independently reports 5-JS1f; headwater and velocity differ by 0.007 m and 0.003 m/s. Deeper submerged cases pass the HGL-at-inlet check, retain 4-FFf, and do not carry a mixed-profile warning.

The explicit Type 6-FFc case is intentionally retained as a limitation rather than an accepted match. The local result identifies 9.991 m of the 10 m barrel as full and its outlet velocity differs from HY-8 by 0.002 m/s, but its HDS-5 inlet-control headwater is 0.414 m below HY-8. The local full-flow outlet-control candidate is lower again, so the discrepancy is associated with the governing high-head inlet calculation, not the full-section velocity. The result retains its short M2 outlet reach and no longer emits an unresolved-profile warning merely because inlet control governs. Both harnesses select the semantically equivalent circular-CSP square-edge-with-headwall inlet. At q* = 13.893, the local solver uses direct HDS-5 Equation A.3 and now attaches inlet_control_high_head_extension because the resulting HW/D exceeds 3. HY-8 reports its polynomial/general-orifice extension instead. The precise closed-executable behavior has not been independently reconstructed, so the 0.414 m difference is an explained method difference rather than a calibration target. It remains inappropriate to tune the published HDS-5 coefficients to this one HY-8 result.

CS-008 discrepancy sweeps (2026-09-09)

The focused nearby-discharge evidence is retained in validation_data/hy8_8_0_1_2_discrepancy_sweep.csv. It used the same executable, run-hy8 source commit, geometry, coefficient mappings, tailwaters, profile option, and report-field checks as the 20-case matrix. Python 3.14.6 ran with bytecode generation disabled. Raw .hy8, .rst, .rsql, and .plt files were retained during the audit in the ignored per-case workspace; the repository CSV preserves the inputs and parsed diagnostics without machine-specific project data.

After the pinned wheel was installed in the Python 3.14 user environment, both artifacts were executed again with PYTHONPATH cleared. Installation metadata identifies run-hy8 2026.9.8.1 and wheel SHA-256 efacb82b13f0fc07fa239a9db91a3e329e87f6622e53e3c5d92525848ca70a1e. The installed-package outputs matched the retained files byte-for-byte: the 20-row matrix has SHA-256 dab7c2ef33ce551ae66fa4b74c879e11404dfcc45c78577910452e005abdc590, and the 27-row sweep has SHA-256 1d93678c0acac656a1bc4a37d0b740d9ed7bf752897fb38aa847e6c4a8c6b7be.

The circular-CSP Type 6 sweep covers nine discharges from 3.80 to 5.20 m³/s, including the original 4.63 m³/s case. HY-8 remains 6-FFc, the local result remains submerged inlet control with its high-head-extension warning, and no HY-8 qualifier appears at any point. The local-minus-HY-8 inlet-depth difference changes monotonically from -0.223 m to -0.563 m; local outlet-control depth remains within 0.012 m, and local full length remains within 0.036 m of HY-8's reported 10.00 m. This is a smooth, discharge-dependent high-head inlet-method difference, not a flow-type transition, outlet-control defect, or report-parser defect. Its disposition is explained method difference: direct HDS-5 Equation A.3 versus HY-8's closed polynomial/general-orifice extension, with the latter still not adopted as a calibration target.

The long circular M2/full sweep covers 18 discharges from 2.60 to 3.40 m³/s, including 0.01 m³/s spacing from 3.20 through 3.30 m³/s. Every HY-8 result remains 7-M2c and every local result remains an outlet-control mixed M2/full profile. Both reported full lengths increase continuously with discharge. The local-minus-HY-8 full-length difference ranges from -2.318 m at 2.60 m³/s to -0.027 m at 3.30 m³/s; its nonlinear narrowing near 3.20 to 3.25 m³/s does not coincide with a flow-type branch change. Outlet-control headwater stays within 0.008 m throughout. Raw .plt crown points agree with the parsed full lengths, ruling out a parser defect. Together with the CS-004 continuous-energy integration, this is disposed as an explained profile-method detail rather than a local defect: HY-8 and the direct-step method place the crown intersection differently while closely agreeing on the governing headwater.

HY-8 uses a fitted fifth-degree inlet curve for the compared shapes (User Manual sections 5.2.1.1-5.2.1.2 and Appendix 11.3), whereas this project currently evaluates the HDS-5/NBS equations directly. Their differences are recorded as method differences, not automatically treated as defects. The initial harness also revealed and fixed a test-configuration error: its fixed road crest intersected the arbitrary box-culvert datum and allowed roadway flow. The harness now places the crest above each case.

At q* = 3.75, the tangent bridge differs from HY-8 by 0.0003 m for the circular concrete case and 0.057 m for the concrete box. This supports the expected distinction between the HDS-5 branch/tangent implementation and HY-8's fitted shape-specific curves; it is not evidence that one universal correction should be applied.

Run the comparison from the repository root with run-hy8 2026.9.8.1 installed. The editable local package or an explicit src path must resolve culvert_solver; no run-hy8 source-path override is required:

$env:PYTHONDONTWRITEBYTECODE = '1'
python -B scripts/compare_hy8.py `
  --workspace validation_artifacts/hy8-matrix `
  --output docs/validation_data/hy8_8_0_1_2_matrix.csv

python -B scripts/compare_hy8.py `
  --workspace validation_artifacts/hy8-discrepancy-sweep `
  --discrepancy-sweep `
  --output docs/validation_data/hy8_8_0_1_2_discrepancy_sweep.csv

HY-8 project/report artifacts are intentionally ignored because they are regenerable and include machine-specific execution output. The explicit output option writes UTF-8 independently of the invoking shell's redirection rules. This matrix is diagnostic evidence, not an acceptance tolerance or engineering validation. The retained CSV includes profile codes, jump stations, stable local warning codes, HY-8 inlet/outlet candidate depths and qualifiers, and HY-8 full/free barrel lengths. CS-003 has classified the Type 6 headwater discrepancy as a warned high-head method difference. CS-004 independently validated the supported prismatic profile families and mixed crown transition. CS-008 reproduced both differences, established their nearby-discharge behavior, and disposed them as explained method differences without tuning the local equations.

Further HEC-RAS, SWMM and STREAM-1D comparisons remain deferred. Pin versions, inputs, units, coefficient mappings, method options and output precision. Agreement does not override primary equations. No external acceptance is claimed.

Historical cases under docs/legacy/ are scenario ideas, not new golden values.